:: TRANSDUCER PRODUCTS / Dual Beam Transducers MODEL 153 Series
5 FREQUENCY OPTIONS
DUAL BEAM
LONG RANGE ECHO SOUNDING
GROUND DISCRIMINATION OPTION
HIGH PERFORMANCE
LOW COST
Click to Enlarge Image
Available in five different frequencies the design has nineteen piston elements arranged in three concentric rings to provide a high performance, dual beam Transducer.

Continuing the company's successful policy of offering transducers with a choice of frequencies the 153 SERIES gives the customer maximum flexibility with minimum cost.

The design is also available as a single, narrow beam transducer.

The versatility of the design is further enhanced with the option of a ground discriminating ’GD’ feature where additional knowledge of the sea floor texture is important.

:: Product Image
:: CAD Diagram
:: Request PDF
:: Request Quotation
Technical Specification
Frequency 24 kHz 28 kHz 30 kHz 33 kHz 38 kHz  kHz
Beam Angle @ -3dB (Wide) 23 19 18 16.5 14 Degrees
Beam Angle @ -3dB (Narrow) 14.5 12 11 10 9 Degrees
Source Level (Wide) 167 168 168 167 165 dB re uPa/V @ 1m
Source Level (Narrow) 170 171 171 170 171 dB re uPa/V @ 1m
Receive Sensitivity -164 -166 -167 -168 -169 dB re V/uPa
Input Power 5000 5000 5000 5000 5000 Watts
Bandwidth 2.8 3.5 3.0 3.5 3.5 kHz
Nominal Impedance 75 100 100 100 100 Ohms
Transducer impedance can be adjusted to suit customers specification
Cable Length 10 metres standard
(Additional lengths supplied to order)
Cable Type Polyurethane Ø12mm 4 Core Screened
Storage Temperature -40 to +80°C
Operating Temperature -5 to +70°C
Ordering Information
153, frequency, with or without 'GD' option, cable length 
 
   
       
       
   